Product Details
Name:
G.E.N.T.L.E-M.A.X Pro Yag 1064nm + 755nm Alexandrite For Hair Remove Laser Machine
Energy:
100J @ 1064nm, 60J@755nm
Laser Sourcing:
Alexandrite Rod + Nd Yag Rod And 2 Pair Of Flash Lamps
Headpiece Cooling:
DCD Cooling+fan Cooling
Water Temperature:
5-25 OC Auto Control
Power Supply Part:
3680 Watts
Product Description

Beauty Equipment G.E.N.T.L.E-M.A.X Pro Yag 1064nm + 755nm Alexandrite For Hair Removal

 

DCD Cryogen 1064nm Yag G.E.N.T.L.E-M.A.X Pro Laser 755nm Alexandrite Long Pulse Width 0

 
DCD Cryogen 1064nm Yag G.E.N.T.L.E-M.A.X Pro Laser 755nm Alexandrite Long Pulse Width 0


 

1. Instrument name: Long pulse width 755 alexandrite laser

2. Technical advantages: unique patent DCD dynamic cooling technology, hair removal is not afraid of scald, red, swelling and pain, no need to apply any media before hair removal, the whole process is painless, cool and comfortable, straight hit the hair root will never regenerate.Suspension depilation is light or not on the skin, not restricted by the head and body bone parts.

3. Treatment parameters:

Items Details
Control  
Monitor 10 inches Digital Real Color LCD
Interface Touch
Control system Single chip
Headpiece  
Headpiece/spot-size Headpiece with slider, lens cap=6,8,10mm, lens cap=12,15,18mm
Large Spot-size 20,22,24mm (optional)
Fiber with slider My by Thorlabs US, 1.6mm diameter with 2600mm length
Protect window Sapphire window
Distance Gauge 18mm, 24mm(optional)
DCD Cooling  
Canisters amount One Dozen (12 bottles), US Type
Canisters Charge Pre-charged or Pre-vacuumed
Canisters color Yellow, Green, Blue, or Black
Cryogenic amount 1 Kg
Cryogenic shots About 20,000 shots
Valve Fixed inside headpiece, US Type
DCD heat up Auto control
DCD pressure Auto control
DCD pulse duration 10-60ms
DCD Pulse interval 10-60ms
Calibration  
Cali port Inside chamber and headpiece holder
Cali degree By each parameter
Water Cooling  
Cooling system Water circulation
Water temperature 5-25 oC auto control
Water tank US type
Filter PP+DI filter
Heat radiator Korea type, two pieces with 2000 watts each
Cooling Fan 3000-6000 R/minute, speed auto control, 4 pices
Chamber  
Wavelength 755nm
Energy 60J@755nm
Lamps amount One Pair
Lamps origin Made by Heraeus UK
Lamps size 10x162mm 770 ppi
Alexandrite Rod 9.53x116mm US Type
ND YAG Rod 9.53x116mm US Type
Pulse frequency 0.5hz, 1Hz,1.5hz,2Hz,5.0hz, 10hz
Pilot beam 520nm green laser
LBO PP-LN
Power system  
Power supply part 3680 watts
IGBT part Made by Infineon Germany
IGBT amount Two
Capacitance capacity 12500+40000uf=52500uf
In charge voltage 750-1400V DC
Voltage input 220V AC
Labels Guide use and safety notice
Size & Weight  
Size 400(W)x800(L)x1150mm(H)
Net weight 95KG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Laser principle: 755nm can effectively pass through the skin to reach the location of the hair follicle, light can stay in the hair follicle for a long time, the hair follicle can fully absorb light energy, so as to achieve the purpose of destroying the hair follicle.The ultra-long pulse width makes the laser energy has sufficient time to destroy the hair shaft, hair follicles and stem cells, to achieve permanent hair removal, because the hair removal process can only be carried out in the hair growth period, and the growth cycle of each hair hair is different, so the whole course of treatment may need 3-6 times of treatment.

5. Treatment range: Suitable for the removal of excess hair on the face, lips, beard, neck, chest, back, legs, arms, armpits, bikini line and other parts of the body.Hair removal of all skin types is the golden wavelength of hair removal in The Middle East of Asia,European, population.The absorption rate of melanin of 755nm laser is higher than that of 800nm semiconductor laser, which is more suitable for the removal of light and fine soft hair, especially for female lip hair removal efficiency is higher.

6. Contraindicated

(1) Infection or history of herpes simplex infection in the treatment area.

(2) Allergic to hydroquinone or other bleach.

(3) Within 6 weeks, patients who had used other methods of hair removal.

(4) A history of keloid.

7. Laser treatment steps

General steps of laser treatment: ① Switch on the power supply and preheat the machine. ② Preparation of the treatment area: before treatment, shave the hair, clean the area and remove oil and dirt. ③ Therapeutic parameters were set and experimental treatment was carried out. ④ Get the best parameters and complete the whole treatment. ⑤ Explain the matters needing attention after operation.

8. Postoperative complications

Side effects of laser hair removal are rare. The most common skin reactions include pain, temporary erythema, and edema around the hair follicle. More serious are blisters, pigmentation, and hypopigmentation, and scarring is rare.

9. Postoperative care

(1) There may be scattered erythema or edema in the area of hair removal after surgery, which need no special care and generally subside within a few hours.

In serious cases, it can be treated with ice.

(2) Pay attention to keep clean after operation, avoid wet water, sunscreen and sunlight within 24 hours.

10. Precautions

(1) The patient's past medical history should be carefully inquired before surgery.

(2) Appropriate eye protection should be done before treatment, including patients, operators and observers in the treatment room.

(3) At the beginning of treatment, the spot should be tested in an inconspicuous area before comprehensive treatment.

DCD Cryogen 1064nm Yag G.E.N.T.L.E-M.A.X Pro Laser 755nm Alexandrite Long Pulse Width 2

 

 

The laser uses a dual-wavelength laser platform that combines a 755nm Alexandrite laser with a 1064nm ND:YAG laser. Combining these two lasers produces a fast, efficient, safe and powerful laser.

 

 

2. Cryo Cooling System and Handle

DCD Cryogen 1064nm Yag G.E.N.T.L.E-M.A.X Pro Laser 755nm Alexandrite Long Pulse Width 3

DCD Cryogen 1064nm Yag G.E.N.T.L.E-M.A.X Pro Laser 755nm Alexandrite Long Pulse Width 4

 

3. Treatment

DCD Cryogen 1064nm Yag G.E.N.T.L.E-M.A.X Pro Laser 755nm Alexandrite Long Pulse Width 5

DCD Cryogen 1064nm Yag G.E.N.T.L.E-M.A.X Pro Laser 755nm Alexandrite Long Pulse Width 6

 

4.Details of Handpiece

The Headpiece is well designed, and the laser spotsizes can be adjusted from 8-16mm diameter, and a continuely headpiece cooling can cool the skin to get down skin tempreture, all that will enables the treatment much more convinent, comfortable and efficient.

DCD Cryogen 1064nm Yag G.E.N.T.L.E-M.A.X Pro Laser 755nm Alexandrite Long Pulse Width 7

5. OEM/ODM Service

Based on our strong R&D and design capabilities, as well as sufficient supply capacity, our company can also provide OEM/ODM services. If you have sufficient strength to become our partner or want to distribute our equipment locally, we will be committed to working with you.

DCD Cryogen 1064nm Yag G.E.N.T.L.E-M.A.X Pro Laser 755nm Alexandrite Long Pulse Width 8

 

 

DCD Cryogen 1064nm Yag G.E.N.T.L.E-M.A.X Pro Laser 755nm Alexandrite Long Pulse Width 9DCD Cryogen 1064nm Yag G.E.N.T.L.E-M.A.X Pro Laser 755nm Alexandrite Long Pulse Width 10DCD Cryogen 1064nm Yag G.E.N.T.L.E-M.A.X Pro Laser 755nm Alexandrite Long Pulse Width 11

 

Send your inquiry directly to us

Privacy Policy China Good Quality Laser Beauty Machine Supplier. Copyright © 2023-2024 laserbeauty-machine.com . All Rights Reserved.