Place of Origin:
Beijing, China
Brand Name:
Snail Medical
Certification:
CE, ROSH
Model Number:
G.E.N.T.L.E-M.A.X Elite
Contact Us
The Alexandrite Laser Series
The New Generation of Laser Hair Remvoal You Never Expected.
755nm and 1064nm lasers for hair removal, vascular and skin rejuvenation.
Dual Wavelength Delivery System
Single, lightweight, ergonomic handpiece deliverying both 755nm and 1064nm wavelength for ultimate treatment convenience.
Multiple Spot Sizes
6,8,10,12,15,18mm spotsizes are anatomically appropriate and offer a wide range of fluence delivery capabilities.
Large Spot Size Delivery
Dual wavelength 20,22, and 24mm spotisze enable shorter treatment times.
Specialty Spot Sizes
Specialty Delivery System option with 1.5, 3 and 3x10mm spots for vascular and pigmented lesions, and 5mm for nail fungus.
DCD---Dynamic Cooling Device
Choose from a cryogen-based Dynamic Cooling Device, which saves time, is operator independent, scales which provides consistant protection of the epidermis.
The skin air cooler adopts a variable frequency air compression fan device to compress the air and then spray cold air through the refrigeration device. The cold air cools the skin to protect the epidermis, reduce pain and enable high energy density without damaging the epidermis.
Please pay attention during operation,
One. Do not blow the same part for a long time to avoid frostbite.
Two. The height of the tuber should be above 8 cm from the skin to prevent frostbite.
Three. Always drain water when transporting and the angle of inclination is no more than 30
degrees.
Four. Do not scrub the panel with alcohol to prevent the writing from falling off.
Five. Do not switch on and off frequently.
Six. Do not switch the machine frequently, and do not start the time interval less than 3 minutes..
Target Color Base Absorbance of Melanin to Different Wavelength of Laser.
Melanin decreases as the wavelength increases, the longer the wavelength, the less menlanin is absorbed. The higher the absorption of melanin, the more obvious the effect.
755nm the Melanin Absorbance Rate is 3.2 times higher than 808nm, 6-8 times than 1064nm.
The deepth of different wavelength of laser compared by Alexandrite Laser 755nm
Absorption of Hemoglobin for Different Wavelength,
High rae of absorption of hemoglobin means the high energy of treatment.
Risks for Side Effect!
Compared with other wavelength, the 755nm alexandrite laser the Hemoglobin Rae is only 0.5, and the ND YAG is only 0.3.
A world leader in hair removal and so much more.
Whatever your business needs, from hair removal to vascular lesions to pigmental lesions, the Gentle Series has a device that is right for you. You can purchase the G.E.N.T.L.E-M.A.X Pro system with its dual laser configuaration or the GentleLase Pro or GENTLE YAG Pro device with the single laser that is the best suited to your patient needs.
Dual 755nm Alexandrite & 1064nm ND YAG Laser
Hair removal and so much more with the combined power and treatment capabilities of GentleLase Pro and Gentle Yag Pro.
755nm Alexandrite Laser
The prefered choice for hair removal in lighter skin types; also recognized for pigmented and vascular lesion removal.
For over 20 years, whenever physician practices, hair removal clinics and medical spas across the globe wanted o provide their patients with the gold standard in laser hair removal and more,
they turned to the Gentle Pro Series.
Today, whatever your business needs, from hair removal to vascular lesions to pigmented lesions, the Gentle Pro Series ahs a device that is right for you.
Patient Satisfaction
A positive experience means patients will be coming back for more and spreading t he word about their Gentle Pro procedures.
Efficiency
Power, speed and larger spot sizes all combine to let your practice treat more patients in less time.
Ease of Use
Great technology always keeps the user in mind, which is why the Gentle Pro series do devices is designed to make it simple for doctors and technicians to treat every patients.
Versatility
While our Gentle Pro devices are best known for hair removal, that's only the beginning of what your practice can offer. Our 755nm and 1064nm wavelength laser technology also treats:
. Pigmented lesions
. Redness and Facial Vessles
. Spiders and Leg Veins
. Wrinkles
. Onychomycosis (nail fungus)
Based on our strong R&D and design capabilities, as well as sufficient supply capacity, our company can also provide OEM/ODM services. If you have sufficient strength to become our partner or want to distribute our equipment locally, we will be committed to working with you.
Items | Details |
Control | |
Monitor | 10 inches Digital Real Color LCD |
Interface | Touch |
Control system | Single chip |
Headpiece | |
Headpiece/spot-size | Headpiece with slider, lens cap=6,8,10mm, lens cap=12,15,18mm |
Large Spot-size | 20,22,24mm (optional) |
Fiber with slider | My by Thorlabs US, 1.6mm diameter with 2600mm length |
Protect window | Sapphire window |
Distance Gauge | 18mm, 24mm(optional) |
ACC Cooling | |
Air Skin Cooler | |
Speed control | 1-9 degrees |
Air Tempreture | Below -25oC |
Air Volume | 2 square meter/min maxium |
Refrigerant | 404A Freon |
Input Power | 800 watts |
Voltage | AC 110-220V Single pulse |
Net Weight | 55kg |
Noise | <70 Db |
Size | 540x400x1160mm |
Calibration | |
Cali port | Inside chamber and headpiece holder |
Cali degree | By each parameter |
Water Cooling | |
Cooling system | Water circulation |
Water temperature | 5-25 oC auto control |
Water tank | US type |
Filter | PP+DI filter |
Heat radiator | Korea type, two pieces with 2000 watts each |
Cooling Fan | 3000-6000 R/minute, speed auto control, 4 pices |
Chamber | |
Wavelength | 755nm+1064nm |
Energy | 100J @ 1064nm, 60J@755nm |
Lamps amount | Two pairs |
Lamps origin | Made by Heraeus UK |
Lamps size | 10x162mm 770 ppi |
Alexandrite Rod | 9.53x116mm US Type |
ND YAG Rod | 9.53x116mm US Type |
Pulse frequency | 0.5hz, 1Hz,1.5hz,2Hz,5.0hz, 10hz |
Pilot beam | 520nm green laser |
LBO | PP-LN |
Power system | |
Power supply part | 3680 watts |
IGBT part | Made by Infineon Germany |
IGBT amount | Two |
Capacitance capacity | 12500+40000uf=52500uf |
In charge voltage | 750-1400V DC |
Voltage input | 220V AC |
Alarm | |
Water circulation | Yes |
Water speed | Yes |
Water temperature | 50oC |
Water purity | Yes |
Fiber insert | Yes |
DCD over heat | Yes |
DCD over charge | Yes |
DCD Pressure | Yes |
Lamp over load | Yes |
Simmer | Yes |
Calibration fail | Yes |
Maintaince | Yes |
Labels | |
Labels | Guide use and safety notice |
Size & Weight | |
Size | 400(W)x800(L)x1150mm(H) |
Net weight | 95KG |
Temperature and humidity
Working temperature: 10-30oC
keep temperature: 0-55oC
Working Relative Humidity:max 80%
Storage relative humidity: Max 90%
Atmospheric pressure: 860hPA—1060hPA
Environmental requirements: Avoid the sunshine
8. FAQ
G.E.N.T.L.E-M.A.X Pro 755nm Alexandrite Laser + 1064nm ND YAG Laser DCD Cooling for Hair Removal and Skin Rejuvenation
Q1. Can I have a sample order for G.E.N.T.L.E-M.A.X Pro?
A: Yes, we welcome sample order to test and check quality.
Q2. What about the lead time?
A: 10-14 days for Sample preparing, 14-28 working days for mass production.
Q3. Do you have any MOQ limit for G.E.N.T.L.E-M.A.X Pro order?
A: Low MOQ, 1pc for sample checking is available.
Q4. How do you ship the goods and how long does it take to arrive?
A: Ship by DHL, UPS, FedEx or TNT. It takes 7-10 days to arrive. Airline and sea shipping also optional.
Q5. How to precede an order for G.E.N.T.L.E-M.A.X Pro?
A: Firstly, let us know your requirements or application.
Secondly, we quote according to your requirements or our suggestions.
Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.
Q6. Is it OK to print my logo on the front cover and on the headpiece?
A: Yes. Please inform us formally before our production.
Q7: Do you offer warranty for the products?
A: Yes, we offer 1 million shots or one year warranty for quality.
Q8: How to deal with the faulty?
A: Firstly, our products are produced in strict quality control system and the defective rate will be less than 0.2%.
Secondly, during the warranty period, we will ask or local service to contact you. If your location is far away from our local service, we will arrange engineers to check online and offer you technical solutions, and we will ship you newly parts without costs to replace.
Send your inquiry directly to us