Place of Origin:
Beijing, China
Brand Name:
Snail Medical
Certification:
CE, TUV
Model Number:
G.E.N.T.L.E-M.A.X Pro
Contact Us
1. Instrument name: Long pulse width 755 alexandrite laser
2. Technical advantages: unique patent DCD dynamic cooling technology, hair removal is not afraid of scald, red, swelling and pain, no need to apply any media before hair removal, the whole process is painless, cool and comfortable, straight hit the hair root will never regenerate.Suspension depilation is light or not on the skin, not restricted by the head and body bone parts.
3. Treatment parameters:
(1) Laser type: emerald laser system, wavelength 755nm,
The energy, pulse width, frequency and spot diameter are adjusted and controlled by computer.
(2) Input power: 4000W energy 8-60J/cm2
(3) Pulse width 1-100ms, frequency 0.5-2.0Hz
(4) Cooling system: water cooling + air cooling +DCD cooling
(5) Spot area is round, diameter 6-18mm
(6) Screen: 10.4 inch touch color screen
4. Laser principle: 755nm can effectively pass through the skin to reach the location of the hair follicle, light can stay in the hair follicle for a long time, the hair follicle can fully absorb light energy, so as to achieve the purpose of destroying the hair follicle.The ultra-long pulse width makes the laser energy has sufficient time to destroy the hair shaft, hair follicles and stem cells, to achieve permanent hair removal, because the hair removal process can only be carried out in the hair growth period, and the growth cycle of each hair hair is different, so the whole course of treatment may need 3-6 times of treatment.
5. Treatment range: Suitable for the removal of excess hair on the face, lips, beard, neck, chest, back, legs, arms, armpits, bikini line and other parts of the body.Hair removal of all skin types is the golden wavelength of hair removal in The Middle East of Asia,European, population.The absorption rate of melanin of 755nm laser is higher than that of 800nm semiconductor laser, which is more suitable for the removal of light and fine soft hair, especially for female lip hair removal efficiency is higher.
6. Contraindicated
(1) Infection or history of herpes simplex infection in the treatment area.
(2) Allergic to hydroquinone or other bleach.
(3) Within 6 weeks, patients who had used other methods of hair removal.
(4) A history of keloid.
7. Laser treatment steps
General steps of laser treatment: ① Switch on the power supply and preheat the machine.② Preparation of the treatment area: before treatment, shave the hair, clean the area and remove oil and dirt.③ Therapeutic parameters were set and experimental treatment was carried out.④ Get the best parameters and complete the whole treatment.⑤ Explain the matters needing attention after operation.
8. Postoperative complications
Side effects of laser hair removal are rare. The most common skin reactions include pain, temporary erythema, and edema around the hair follicle. More serious are blisters, pigmentation, and hypopigmentation, and scarring is rare.
9. Postoperative care
(1) There may be scattered erythema or edema in the area of hair removal after surgery, which need no special care and generally subside within a few hours.
In serious cases, it can be treated with ice.
(2) Pay attention to keep clean after operation, avoid wet water, sunscreen and sunlight within 24 hours.
10. Precautions
(1) The patient's past medical history should be carefully inquired before surgery.
(2) Appropriate eye protection should be done before treatment, including patients, operators and observers in the treatment room.
(3) At the beginning of treatment, the spot should be tested in an inconspicuous area before comprehensive treatment.
Dear customer .Welcome to Snail Medical.
Working Principle
Large areas of the body tend to recover faster.
1: Suitable for any color of hair
2: Suitable for all of skin type (I, II,III, IV, V, VI.)
3: Alexandite laser hair removal—Safe .Fast , high efficiency
4: International Hair Removal Standard.
5: Permanent hair removal
6:Treat red and blue vessel no matter larger deeper or small superIcial
7: Skin rejuvenation(port wine strains, skin capillaries and etc)
8: Removal pigmentation
Based on our strong R&D and design capabilities, as well as sufficient supply capacity, our company can also provide OEM/ODM services. If you have sufficient strength to become our partner or want to distribute our equipment locally, we will be committed to working with you.
Items | Details |
Control | |
Monitor | 10 inches Digital Real Color LCD |
Interface | Touch |
Control system | Single chip |
Headpiece | |
Headpiece/spot-size | Headpiece with slider, lens cap=6,8,10mm, lens cap=12,15,18mm |
Large Spot-size | 20,22,24mm (optional) |
Fiber with slider | My by Thorlabs US, 1.6mm diameter with 2600mm length |
Protect window | Sapphire window |
Distance Gauge | 18mm, 24mm(optional) |
DCD Cooling | |
Canisters amount | One Dozen (12 bottles), US Type |
Canisters Charge | Pre-charged or Pre-vacuumed |
Canisters color | Yellow, Green, Blue, or Black |
Cryogenic amount | 1 Kg |
Cryogenic shots | About 20,000 shots |
Valve | Fixed inside headpiece, US Type |
DCD heat up | Auto control |
DCD pressure | Auto control |
DCD pulse duration | 10-60ms |
DCD Pulse interval | 10-60ms |
Calibration | |
Cali port | Inside chamber and headpiece holder |
Cali degree | By each parameter |
Water Cooling | |
Cooling system | Water circulation |
Water temperature | 5-25 oC auto control |
Water tank | US type |
Filter | PP+DI filter |
Heat radiator | Korea type, two pieces with 2000 watts each |
Cooling Fan | 3000-6000 R/minute, speed auto control, 4 pices |
Chamber | |
Wavelength | 755nm |
Energy | 60J@755nm |
Lamps amount | One Pair |
Lamps origin | Made by Heraeus UK |
Lamps size | 10x162mm 770 ppi |
Alexandrite Rod | 9.53x116mm US Type |
ND YAG Rod | 9.53x116mm US Type |
Pulse frequency | 0.5hz, 1Hz,1.5hz,2Hz,5.0hz, 10hz |
Pilot beam | 520nm green laser |
LBO | PP-LN |
Power system | |
Power supply part | 3680 watts |
IGBT part | Made by Infineon Germany |
IGBT amount | Two |
Capacitance capacity | 12500+40000uf=52500uf |
In charge voltage | 750-1400V DC |
Voltage input | 220V AC |
Alarm | |
Water circulation | Yes |
Water speed | Yes |
Water temperature | 50oC |
Water purity | Yes |
Fiber insert | Yes |
DCD over heat | Yes |
DCD over charge | Yes |
DCD Pressure | Yes |
Lamp over load | Yes |
Simmer | Yes |
Calibration fail | Yes |
Maintaince | Yes |
Labels | |
Labels | Guide use and safety notice |
Size & Weight | |
Size | 400(W)x800(L)x1150mm(H) |
Net weight | 95KG |
Q1. Can I have a sample order for G.E.N.T.L.E-M.A.X Pro?
A: Yes, we welcome sample order to test and check quality.
Q2. What about the lead time?
A: 10-14 days for Sample preparing, 14-28 working days for mass production.
Q3. Do you have any MOQ limit for GentleLase Pro order?
A: Low MOQ, 1pc for sample checking is available.
Q4. How do you ship the goods and how long does it take to arrive?
A: Ship by DHL, UPS, FedEx or TNT. It takes 7-10 days to arrive. Airline and sea shipping also optional.
Q5. How to precede an order for GentleLase Pro?
A: Firstly, let us know your requirements or application.
Secondly, we quote according to your requirements or our suggestions.
Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.
Q6. Is it OK to print my logo on the front cover and on the headpiece?
A: Yes. Please inform us formally before our production.
Q7: Do you offer warranty for the products?
A: Yes, we offer 1 million shots or one year warranty for quality.
Q8: How to deal with the faulty?
A: Firstly, our products are produced in strict quality control system and the defective rate will be less than 0.2%.
Secondly, during the warranty period, we will ask or local service to contact you. If your location is far away from our local service, we will arrange engineers to check online and offer you technical solutions, and we will ship you newly parts without costs to replace.
Send your inquiry directly to us