Place of Origin:
Beijing, China
Brand Name:
Snail Medical
Certification:
CE, TUV
Model Number:
G.E.N.T.L.E-M.A.X Pro
Contact Us
What is an alexandrite laser?
1. Instrument name: Long pulse width 755 alexandrite laser
2. Technical advantages: unique patent DCD dynamic cooling technology, hair removal is not afraid of scald, red, swelling and pain, no need to apply any media before hair removal, the whole process is painless, cool and comfortable, straight hit the hair root will never regenerate.Suspension depilation is light or not on the skin, not restricted by the head and body bone parts.
3. Technical Parameters:
Items | Details |
Control | |
Monitor | 10 inches Digital Real Color LCD |
Interface | Touch |
Control system | Single chip |
Headpiece | |
Headpiece/spot-size | Headpiece with slider, lens cap=6,8,10mm, lens cap=12,15,18mm |
Large Spot-size | 20,22,24mm (optional) |
Fiber with slider | My by Thorlabs US, 1.6mm diameter with 2600mm length |
Protect window | Sapphire window |
Distance Gauge | 18mm, 24mm(optional) |
DCD Cooling | |
Canisters amount | One Dozen (12 bottles), US Type |
Canisters Charge | Pre-charged or Pre-vacuumed |
Canisters color | Yellow, Green, Blue, or Black |
Cryogenic amount | 1 Kg |
Cryogenic shots | About 20,000 shots |
Valve | Fixed inside headpiece, US Type |
DCD heat up | Auto control |
DCD pressure | Auto control |
DCD pulse duration | 10-60ms |
DCD Pulse interval | 10-60ms |
Calibration | |
Cali port | Inside chamber and headpiece holder |
Cali degree | By each parameter |
Water Cooling | |
Cooling system | Water circulation |
Water temperature | 5-25 oC auto control |
Water tank | US type |
Filter | PP+DI filter |
Heat radiator | Korea type, two pieces with 2000 watts each |
Cooling Fan | 3000-6000 R/minute, speed auto control, 4 pices |
Chamber | |
Wavelength | 755nm |
Energy | 60J@755nm |
Lamps amount | One Pair |
Lamps origin | Made by Heraeus UK |
Lamps size | 10x162mm 770 ppi |
Alexandrite Rod | 9.53x116mm US Type |
ND YAG Rod | 9.53x116mm US Type |
Pulse frequency | 0.5hz, 1Hz,1.5hz,2Hz,5.0hz, 10hz |
Pilot beam | 520nm green laser |
LBO | PP-LN |
Power system | |
Power supply part | 3680 watts |
IGBT part | Made by Infineon Germany |
IGBT amount | Two |
Capacitance capacity | 12500+40000uf=52500uf |
In charge voltage | 750-1400V DC |
Voltage input | 220V AC |
Labels | Guide use and safety notice |
Size & Weight | |
Size | 400(W)x800(L)x1150mm(H) |
Net weight | 95KG |
4.Treatment principle: 755nm can effectively pass through the skin to reach the location of the hair follicle, light can stay in the hair follicle for a long time, the hair follicle can fully absorb light energy, so as to achieve the purpose of destroying the hair follicle.The ultra-long pulse width makes the laser energy has sufficient time to destroy the hair shaft, hair follicles and stem cells, to achieve permanent hair removal, because the hair removal process can only be carried out in the hair growth period, and the growth cycle of each hair hair is different, so the whole course of treatment may need 3-6 times of treatment.
5. Treatment range: Suitable for the removal of excess hair on the face, lips, beard, neck, chest, back, legs, arms, armpits, bikini line and other parts of the body.Hair removal of all skin types is the golden wavelength of hair removal in The Middle East of Asia,European, population.The absorption rate of melanin of 755nm laser is higher than that of 808nm semiconductor laser, which is more suitable for the removal of light and fine soft hair, especially for female lip hair removal efficiency is higher.
6. Contraindicated
(1) Infection or history of herpes simplex infection in the treatment area.
(2) Allergic to hydroquinone or other bleach.
(3) Within 6 weeks, patients who had used other methods of hair removal.
(4) A history of keloid.
7. Postoperative complications
Side effects of laser hair removal are rare. The most common skin reactions include pain, temporary erythema, and edema around the hair follicle. More serious are blisters, pigmentation, and hypopigmentation, and scarring is rare.
The laser uses a dual-wavelength laser platform that combines a 755nm Alexandrite laser with a 1064nm ND:YAG laser. Combining these two lasers produces a fast, efficient, safe and powerful laser.
4.Details of Handpiece
The Headpiece is well designed, and the laser spotsizes can be adjusted from 8-16mm diameter, and a continuely headpiece cooling can cool the skin to get down skin tempreture, all that will enables the treatment much more convinent, comfortable and efficient.
Based on our strong R&D and design capabilities, as well as sufficient supply capacity, our company can also provide OEM/ODM services. If you have sufficient strength to become our partner or want to distribute our equipment locally, we will be committed to working with you.
1.What is the treatment Steps of Gentlase or G.E.N.T.L.E-M.A.X Pro
General steps of laser treatment: ① Switch on the power supply and preheat the machine.② Preparation of the treatment area: before treatment, shave the hair, clean the area and remove oil and dirt.③ Therapeutic parameters were set and experimental treatment was carried out.④ Get the best parameters and complete the whole treatment.⑤ Explain the matters needing attention after operation.
2.What should be do to patients before and after treatment ?
Precautions
(1) The patient's past medical history should be carefully inquired before surgery.
(2) Appropriate eye protection should be done before treatment, including patients, operators and observers in the treatment room.
(3) At the beginning of treatment, the spot should be tested in an inconspicuous area before comprehensive treatment.
Postoperative care
(1) There may be scattered erythema or edema in the area of hair removal after surgery, which need no special care and generally subside within a few hours.
In serious cases, it can be treated with ice.
(2) Pay attention to keep clean after operation, avoid wet water, sunscreen and sunlight within 24 hours.